Please use this identifier to cite or link to this item: http://localhost:8080/xmlui/handle/123456789/1024
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHasan, Muhideen Abbas-
dc.contributor.authorThiyab, Munther Naif-
dc.contributor.authorKeream, Settar S.-
dc.contributor.authorAbid, Kaleid W.-
dc.date.accessioned2022-10-15T08:02:01Z-
dc.date.available2022-10-15T08:02:01Z-
dc.date.issued2020-
dc.identifier.issn2502-4752-
dc.identifier.urihttp://localhost:8080/xmlui/handle/123456789/1024-
dc.description.abstractAbstract: Photoplethysmography (PPG) sensors are widely used in medical applications due to their attractive properties such as non-invasiveness, inexpensive, and easy setup. However, they are still inefficient in non-stationary states of important measurements related to cardiovascular assessment. Adaptive noise cancellation (ANC) has existed as a kind of technique to address this issue. Unfortunately, the traditional 3-Axis Accelerometer (ACC) in ANC implementation has failed to provide the real motion artifact (MA) as the main factor for efficient adaptive filtering. In this work, the performance of ACC will be investigated and compared with a new twin photodiodes PPG probe design (TPs-PPD) that has been proven in previous work. The TPs-PPD contained an added covered photodiode (CPD) customized to obtain the MA instead of classic use of ACC. During different motions, PPG data were recorded and processed at the same time by the same two units of adaptive filters using ACC and CPD as noise references. The results indicated a clear failure of the ACC compared to the CPD in determining important features of PPG signal, in addition to the accuracy of signal to noise ratio (SNR) and mean square error (MSE). The CPD was better than ACC as it reduced the MSE by 14 times while the SNR was multiplied 10 times. Without any doubt, it has been proven with evidence that the ACC is not suitable for the processing of human health-related signals while PPG can be used for such purposes.en_US
dc.language.isoenen_US
dc.publisherIndonesian Journal of Electrical Engineering and Computer Scienceen_US
dc.subjectAccelerometeren_US
dc.subjectAdaptive noise cancellationen_US
dc.subjectCovered photo-detectoren_US
dc.subjectNoise reflectoren_US
dc.subjectPPG signalsen_US
dc.titleAn evaluation of the accelerometer output as a motion artifact signal during photoplethysmograph signal processing controlen_US
dc.typeArticleen_US
Appears in Collections:الهندسة الكهربائية

Files in This Item:
File Description SizeFormat 
Abstract4.pdf28.58 kBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.