Please use this identifier to cite or link to this item:
http://localhost:8080/xmlui/handle/123456789/3890
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | AL-Kubaysi, Ghassan Subhi | - |
dc.date.accessioned | 2022-10-20T12:06:22Z | - |
dc.date.available | 2022-10-20T12:06:22Z | - |
dc.date.issued | 2008 | - |
dc.identifier.uri | http://localhost:8080/xmlui/handle/123456789/3890 | - |
dc.description | Master Thesis | en_US |
dc.description.abstract | This research includes the study improvement of the mechanical properties and resistance to high temperatures of concrete using steel fibers with different ratios of volume (0.5%, 1%, 1.5%) and polymer with different weight ratios of polymer to cement (3%, 7%, 10%). The samples were made as follows: (100, 100, 100mm) cubes for compressive strength tests, (100, 200mm) cylinders for splitting tensile strength tests and (100, 100, 500mm) prisms for flexural strength tests. The results show an improvement in all properties of steel fiber concrete with and without polymer as compared with reference concrete. In compressive strength, the increase was (14.2% - 40.6%) for steel fiber concrete, while the increase was (44.8% - 86.64%) for steel fiber concrete containing polymer. In splitting tensile strength, the increase was (50% - 91%) for steel fiber concrete, while the increase was (102.4% - 124.7%) for steel fiber concrete containing polymer. For flexural strength, the increase was (24.2% - 48.3%) for steel fiber concrete, while the increase was (62% - 78%) for steel fiber concrete containing polymer. As concerns the effect of temperature on concrete tests, steel fiber concrete containing polymer gained compressive, tensile, and flexural strength greater than reference concrete specimens for all temperatures (100, 300, 500, 700Cْ ). The increase in compressive strength was (82%, 54%, 69.8%, 171.4%), respectively; while the increase in tensile strength was ( 119.2%, 132.6%, 99%, 52.3%), respectively; and the increase in flexural strength was ( 87.3%, 194.4%, 115.8%, 164%), respectively. | en_US |
dc.language.iso | en | en_US |
dc.title | Mechanical and Some Thermal Properties of Fiber Concrete Containing Polymer | en_US |
dc.type | Thesis | en_US |
Appears in Collections: | الهندسة المدنية |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
ماجستير غسان.pdf | 1.47 MB | Adobe PDF | View/Open |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.