Please use this identifier to cite or link to this item: http://localhost:8080/xmlui/handle/123456789/4498
Title: Thermal Performance of a Heat Pipe with Sintered Powder Metal Wick Using Ethanol and Water as Working Fluids
Authors: T Fadhil, Obaid
Issue Date: 2011
Publisher: Anbar Journal for Engineering Sciences
Abstract: An experimental study is carried out to compare the thermal performance of a sintered powder metal wick heat pipe. Pure water and absolute ethanol are used as two different working fluids. The pipe is made of copper with 300 mm length, 14 mm diameter, and 1.0 mm wall thickness. The wick is made of copper powder. All the experiments are accomplished and the heat pipe is at the horizontal position (θ=0o ). The heat flux changed within the range (2.8 -13.13) kW/m2 , while all other conditions remained constant. The results show that the thermal performance of the heat pipe is better when water is the working fluid, where the operating temperature and the thermal resistance of the heat pipe are lower when the water is the working fluid.
URI: http://localhost:8080/xmlui/handle/123456789/4498
Appears in Collections:الهندسة الميكانيكية

Files in This Item:
File Description SizeFormat 
Abstract.docx13.23 kBMicrosoft Word XMLView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.