dc.description.abstract | In this research a study effect of the length ratio (L/Da) and the height ratio (H/Da) for banks flat tube heat exchanger In-Line and staggered arrangement on force convection heat transfer and friction coefficient by (Fluent-CFD) numerical program. The governing equations (mass, momentum and energy) are solving by using Finite Volume (Fluent-CFD) software for considering steady state, two dimensional, at constant heat flux with Reynold’s number (100≤Re≤8000). The results show that increasing (H/Da), (L/Da) lead to decreasing friction coefficient and enhancement of (Nu) is at (H/Da=2) for all (L/Da) values In-line arrangement and at (H/Da =2, L/Da =5) for staggered arrangement. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Tikrit Journal of Engineering Sciences | en_US |
dc.subject | convection heat transfer | en_US |
dc.subject | banks flat tubes | en_US |
dc.subject | and fluid flow | en_US |
dc.title | Heat Transfer and Fluid Flow Characteristic in banks Flat Tubes | en_US |