Please use this identifier to cite or link to this item: http://localhost:8080/xmlui/handle/123456789/5122
Full metadata record
DC FieldValueLanguage
dc.contributor.authorShareef, Amer Jameel-
dc.contributor.authorRamadhan, Abdulmajeed A.-
dc.date.accessioned2022-10-22T14:53:23Z-
dc.date.available2022-10-22T14:53:23Z-
dc.date.issued2011-
dc.identifier.urihttp://localhost:8080/xmlui/handle/123456789/5122-
dc.description.abstractIn this research a study effect of the length ratio (L/Da) and the height ratio (H/Da) for banks flat tube heat exchanger In-Line and staggered arrangement on force convection heat transfer and friction coefficient by (Fluent-CFD) numerical program. The governing equations (mass, momentum and energy) are solving by using Finite Volume (Fluent-CFD) software for considering steady state, two dimensional, at constant heat flux with Reynold’s number (100≤Re≤8000). The results show that increasing (H/Da), (L/Da) lead to decreasing friction coefficient and enhancement of (Nu) is at (H/Da=2) for all (L/Da) values In-line arrangement and at (H/Da =2, L/Da =5) for staggered arrangement.en_US
dc.language.isoenen_US
dc.publisherTikrit Journal of Engineering Sciencesen_US
dc.subjectconvection heat transferen_US
dc.subjectbanks flat tubesen_US
dc.subjectand fluid flowen_US
dc.titleHeat Transfer and Fluid Flow Characteristic in banks Flat Tubesen_US
dc.typeArticleen_US
Appears in Collections:الهندسة الميكانيكية

Files in This Item:
File Description SizeFormat 
174ammer2011.pdf217.73 kBAdobe PDFView/Open