Title: | Parameters Affecting Bulk Etch Rate VB for CR-39 Detector |
Authors: | R Flaih, Khalid |
Keywords: | "Nuclear detectors CR-39 ; bulk etch rate VB; Chemical etchant NaOH " |
Issue Date: | 24-Aug-2020 |
Publisher: | Journal of University of Anbar for Pure Science (JUAPS) |
Abstract: | "In this work, the dependence of the bulk etches rate VB for CR-39detector on the temperature T, etching time t and concentration N of the NaOH etchant solution has been studied for detectors material types PADC. The concentration, etching time, temperature and other conditions have been varied in the ranges (5.25-8.25) N, (1-5) hand (60-80) °C for PADC respectively. In this case, the thickness of material removed by etching ranges from 0.20 to 6.10𝜇m/hr for CR-39detector.The 6.25 N NaOH solution at 70°C with etching time 3 hours represents the optimum etching condition for nuclear detector CR-39 " |